12 kV Dry Air Insulated Ring Main Unit XDA-12(V)/630-20

SF6-free 12 kV ring main unit using dry air insulation, rated 630 A with 20 kA short-circuit breaking capacity. The source description states a type-tested design; request the model-specific report and scope before relying on that claim.

Standards referenced for project review, not evidence of product certification:

  • IEC 62271-200
  • IEC 62271-100
  • IEC 62271-1
12 kV Dry Air Insulated Ring Main Unit XDA-12(V)/630-20 — Reference equipment image

Reference image for initial review. Confirm the exact model, configuration and ratings before tender use.

Rated voltage
12 kV
Peak withstand current
50 kA peak
Rated operating sequence
O-0.3s-CO-180s-CO
Rated current / frequency
630 A / 50 Hz
Short-circuit making current
50 kA peak
Short-circuit breaking current
20 kA

ENGINEERING VIEW

RMU rating snapshot

A visual summary of published source data. It does not replace the full technical schedule or project confirmation.

Dry airSF6-free insulation
SwitchingThree-position switch + vacuum circuit breaker
Network dutySecondary-distribution review
Rated voltage
12 kV
Rated current / frequency
630 A / 50 Hz
Breaking current
20 kA

Product description

SF6-free 12 kV ring main unit using dry air insulation, rated 630 A with 20 kA short-circuit breaking capacity. The source description states a type-tested design; request the model-specific report and scope before relying on that claim.

Features

  • Dry air insulation — no SF6, no F-gas
  • 20 kA short-circuit breaking current
  • Source description states a type-tested design; request the model-specific report and scope.
  • Three-position switch and vacuum circuit breaker
  • Compact cubicle construction
  • Rated operating sequence O-0.3s-CO-180s-CO

Project fit and quotation

Use the published sheet for initial comparison. Review these project requirements before confirming a configuration.

Network and circuit duties

Share system voltage and frequency, the single-line diagram, and current and short-circuit requirements for each way.

Protection and cable interfaces

Confirm protection functions, auxiliary supply, local or remote operation, cable entry and termination details.

Site conditions and access

Share the installation country, indoor or outdoor location, altitude, ambient temperature range and available space.

NEXT STEP

Specify the equipment.

Voltage class, rated current, short-circuit level, installation environment and the standards your project is tendered against.

Start an RFQ