Products / 03 / Prefabricated Substations
Prefabricated Substation
Compact factory-assembled substation integrating the high voltage compartment, transformer compartment and low voltage compartment in one enclosure, verified to IP44 and IK10.
Standards referenced for project review, not evidence of product certification:
- IEC 62271-202
Reference image for initial review. Confirm the exact model, configuration and ratings before tender use.
PRODUCT VIEWS
Reference views for initial review.
Images support product-family orientation. Confirm the exact configuration, finish and ratings against the current technical schedule.
- Structure
- Three-compartment integrated (HV / transformer / LV)
- Type tests
- Insulation, grounding and temperature-rise tests qualified
- Noise level
- ≤ 45 dB(A) (measured 37 dB(A))
- Configurable
- Rated voltage, transformer capacity, switchgear configuration, enclosure dimensions and protection scheme engineered per project
- Enclosure protection
- IP44
- Mechanical impact resistance
- IK10
ENGINEERING VIEW
Three-compartment substation
A visual summary of published source data. It does not replace the full technical schedule or project confirmation.
- Enclosure protection
- IP44
- Mechanical impact
- IK10
- Configuration
- Project-specific
Product description
Compact factory-assembled substation integrating the high voltage compartment, transformer compartment and low voltage compartment in one enclosure, verified to IP44 and IK10.
Features
- Three-compartment integrated structure
- Compact footprint and convenient transportation
- Factory prefabrication for faster on-site installation
- Suitable for industrial, commercial and infrastructure distribution systems
- Enclosure protection verified to IP44
- Mechanical impact resistance verified to IK10
Test values stated in the product flyer
- Measured noise
- 37 dB(A)
- Enclosure protection
- IP44
- Noise level (requirement)
- ≤ 45 dB(A)
- Mechanical impact resistance
- IK10
- Enclosure mechanical strength
- 2500 N/m² minimum; measured 2600 N/m²
- Insulation / grounding / temperature-rise tests
- Qualified
Technical parameters
| Parameter | Value |
|---|---|
| Structure | Three-compartment integrated (HV / transformer / LV) |
| Type tests | Insulation, grounding and temperature-rise tests qualified |
| Noise level | ≤ 45 dB(A) (measured 37 dB(A)) |
| Configurable | Rated voltage, transformer capacity, switchgear configuration, enclosure dimensions and protection scheme engineered per project |
| Enclosure protection | IP44 |
| Mechanical impact resistance | IK10 |
| Enclosure mechanical strength | ≥ 2500 N/m² (measured 2600 N/m²) |
Parameters are taken from the manufacturer product sheet. Final ratings are confirmed against the project specification before order.
Documented application contexts
These links show the evidence basis currently associated with this product. They are starting points for engineering review, not project references or recommendations.
Frequently asked questions
What is integrated in the substation?
The platform combines high-voltage, transformer and low-voltage compartments in one factory-assembled enclosure.
Which verified enclosure data is available?
Only the enclosure values shown in the technical table above are published for this product. Ask for the model-specific test or drawing reference before relying on any other value.
Are voltage and transformer capacity fixed?
No. Rated voltage, transformer capacity, dimensions, protection scheme and final configuration are project-specific and confirmed during engineering.
Which standards apply?
Review IEC 62271-202 as applicable references. The exact standard scope and supporting test evidence must be confirmed for the quoted configuration.
Project fit and quotation
Use the published sheet for initial comparison. Review these project requirements before confirming a configuration.
Electrical scope and transformer
Share HV and LV voltages, frequency, required capacity and load profile. Identify any specified transformer type.
Enclosure and installation
Share ambient conditions, altitude, footprint, noise limits, and access, ventilation or fire requirements.
Connections and responsibilities
Confirm cable interfaces, foundation details, transport and lifting limits, plus equipment and installation scope.
NEXT STEP
Specify the equipment.
Voltage class, rated current, short-circuit level, installation environment and the standards your project is tendered against.